Card Layout:
The SSCS operates on 115 Volt, 60 Hz AC power to convert synchro inputs into high power synchro outputs. The SSCS accepts two channels of 60 Hz synchro data and two channels of 400 Hz synchro data. Each channel is fault protected against over current and over temperature faults. In addition, the SSCS provides power supply status, BIT status and internal kick circuitry for added control and protection. An onboard microcontroller configures the cards from power up or reset and provides all signals and control to read the synchro input information and output the 125VA synchro/resolver information. Health monitoring of each 1X/36X channel for over-current, over-temperature and loss of reference is provided via visual display indicators. Synchro data formats, power outputs, synchro and resolver voltages and frequencies are factory configured to user requirements.
Technical Specification | ||
Parameter | Value | Units |
Power Input | 115 | Volts AC |
60 | Hertz | |
6.3 | Amps | |
Temperature Range | ||
Operating Temperature | -25 to +85 | °C |
Storage Temperature | -65 to +125 | °C |
Inputs | ||
Reference Input | 115 | Volts |
60/400 | Hertz | |
Synchro (Channel 1 1X , 36X) | 90 | Volts |
60/400 | Hertz | |
Synchro (Channel 2 1X , 36X) | 90 | Volts |
60/400 | Hertz | |
Outputs | ||
Synchro (Channel 1 1X , 36X) | 90 | Volts |
400 | Hertz | |
125 | VA (Peak) | |
30 | VA (Continuous) | |
Synchro (Channel 1 1X , 36X) | 90 | Volts |
60 | Hertz | |
125 | VA (Peak) | |
30 | VA (Continuous) | |
Accuracy | +/- 4 | Arc Minutes |
Physical Characteristics | ||
30.0 x 12.0 x 12.0 | Inches | |
76.2 x 30.48 x 30.48 | Centimeters |